_ZA1P3 FILTER FOR PARTICLES, SOLID & LIQUID AEROSOLS, GASES AND ORGANIC VAPOURS (PACK OF 4 FILTERS)

SKU: 0601070


    As regards the personal and common data subject to processing, in relation to the above information, by selecting the "accept" item below, I declare that I have taken note of the methods in which the data will be processed, and I express my consent to the processing , including the communication of the data being processed for the purposes referred to in sub a). I am also aware that in the absence of such consent Kasco will not be able to provide the requested services.

    Accept - By selecting "accept", I express my consent to the processing, including the communication of personal and common data subject to processing according to the purposes referred to in sub b) in the manner provided for in the information.


    Filter for protection against particles, solid & liquid aerosols and organic vapours – class A1P3.
    Pivoting protection grid for easy decontamination even under the shower.
    Large diameter (110mm) for lower respiratory resistance at same efficiency.

    Connection according to EN 148-1 standard
    Filter certified according to EN 12942 standard

    Sold in packs of 4 filters.

    Specifications UM Value
    Weight [kg] 0,23
    Diameter [mm] 110
    Height [mm] 68
    Respiratory resistance at 30 l/min (<2,6) [mbar] 0,8
    Respiratory resistance at 95 l/min (<9,8) [mbar] 1,9
    Classification according to EN 12942 A1P3
    Marking colour Brown / White
    Threaded connection EN 148-1
    Conforms to REGULATION (EU) 2016/425

     

    Components Material
    Filter housing Polypropylene
    Filter cartridge Technical paper
    Glue Polyurethane
    Activated carbon Type A2

     

    Efficiency according to EN 143 Airflow
    [l/min]
    Type of
    Aerosol
    Max. admissible Penetration [%] Min admissible Efficiency [%] Penetration measured [%]
    (1) (2) (3)
    95 DOP 0,05 99,95 0,0007 0,0008 0,0008
    95 NaCl 0,05 99,95 0,0045 0,0045 0,0015

    (1): Penetration (mean calculated during 30 +/- 3 s sampling after 3 min from the start of the test) ;
    (2): Maximum penetration up to an exposure of 120 mg of aerosol (penetration recorded every 5 min);
    (3): Penetration (mean calculated during 30 +/- 3 s sampling after 3 min from the start of the test) after exposure to 120 mg of aerosol and 24h storage.
    Note: penetration data refers to particles larger than 0.3μm

    Famiglia merceologica

    FILTERS

    Settori

    Agriculture/Nursery/Garden, Chemical/Pharmaceutical/Food, Farms/Zootechnics, Painting/Sandblasting

    Mercato

    CE