CLEANSPACE™ FULL FACE MASK

SKU: PAF-1014


    As regards the personal and common data subject to processing, in relation to the above information, by selecting the "accept" item below, I declare that I have taken note of the methods in which the data will be processed, and I express my consent to the processing , including the communication of the data being processed for the purposes referred to in sub a). I am also aware that in the absence of such consent Kasco will not be able to provide the requested services.

    Accept - By selecting "accept", I express my consent to the processing, including the communication of personal and common data subject to processing according to the purposes referred to in sub b) in the manner provided for in the information.


    Full face mask to combine with CleanSpace EX and CleanSpace ULTRA control units.

    CleanSpace™ full face mask for use with CleanSpace™ Ultra and CleanSpace™ EX control units. Suitable for heavy and/or long-term work. The mask is positive pressure with a sealing body and internal oro-nasal silicone mask for optimal protection of the respiratory tract. The CleanSpace™ full-face mask is compatible with the CleanSpace™ Ultra and CleanSpace™ EX control units; with the full range of CleanSpace™ standard dust filters (P3/TM3); the combined filters (A1P3, ABE1P3) and the prefilters.

    CERTIFICATES

    • AS/NZS1716:2012 PAPR-P3 (Full Face Mask)
    • EN 12942
    • IEC 60529 IP-66
    • AS/NZS 1337.1:2010 Impact resistance

    CHARACTERISTICS

    • To be combined with the revolutionary CleanSpace™ PAPR: light, without tubes and without belts.
    • Large panoramic visor.
    • Anti-scratch and solvent resistant coating.
    • Suitable for wearing for long periods of work.
    • Positive pressure air flow and anti-fog internal oro-nasal mask.
    • Easy breathing and no resistance even during heavy efforts.
    • The silicone seal body is designed to provide optimal protection and comfort.
    • Internal oro-nasal mask with exclusive “clip-in clip-out” system can be easily removed for cleaning.
    • Mylar speech membrane for clear communication in the workplace.
    • Anti-aging materials.
    • Enabling quantitative fit testing on Portacount (sold separately)
    • Safety glasses kit: Fully adjustable for all face sizes, frame for inserting large lenses for peripheral vision; very high stability even during vigorous activities (sold separately).
    • Tear-off visor: Protects the visor from scratches. (Sold separately)

    APPLICATIONS SUITABLE FOR IP 66 PROTECTION DEGREE:

    • Dust: 6. Protection against all dust — ‘dust-proof’; Liquids: 6 Protection against water – powerful jets of water (12.5 mm nozzle) launched against the casing from any direction must not cause any damage. Test duration: at least 3 minutes with water volume at 100 liters per minute, pressure: 100 kPa at a distance of 3 m).
    • The CleanSpace™ Ultra and CleanSpace™ EX full face mask units are suitable for asbestos removal and chemical applications where decontamination showers are used.

    OTHER APPLICATIONS:

    • Specifically designed for use in decontamination operations, particularly where showers are used; for long jobs in places that require very high levels of protection; for activities where eye protection is required. They can also be used for a wide range of other applications; Welding, woodworking, manufacturing, foundries, construction, recycling plants, emergency services, mining, agriculture, processing plants, grinding work.

    LIMITATIONS

    • CleanSpace™ respirators are powered, positive pressure masks and are designed to be worn in environments where the percentage of oxygen is sufficient to breathe safely. Do not use the CleanSpace™ in environments immediately dangerous to life and health (IDLH environments), for protection against gases and/or vapors that CANNOT be filtered, or in oxygen-enriched or oxygen-deficient atmospheres.

    SPECIFICATIONS

    Materials: Rigid visor molded in polycarbonate; sealing body and internal oro-nasal mask in silicone. Nylon mask hooks; Mylar phonic membrane. EPDM rubber harness; exhalation valve seat in reinforced shockproof polypropylene; OR in silicone.
    Weight: 700g
    Note: or use only with CleanSpace™ Ultra and CleanSpace™ EX control units.
    Cleaning: Lukewarm water and mild detergent (pH 6 – 8). Do not use solvents (turpentine or acetone), hot water, bleach or chemical agents.
    Storage: –10°C to +55°C (–4°F to +131°F) at <90% relative humidity. Keep away from direct sunlight, grease and oil.

    SPARE PARTS AND ACCESSORIES AVAILABLE

    Safety glasses kit
    Anti-scratch tear-off visor
    Adapter for Quantitative “Fit Test” (PortaCount)
    Exhalation valve (membrane only) (spare)
    Inner mask (with inhalation valves) (spare)
    Inhalation valve set (6 valves, with respective seats) (spare)
    Harness (spare)

     

    Mercato

    CE

    Famiglia merceologica

    Cleanspace Range